ECLIPSE PICO MATRIXINSTRUCTION MANUAL
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual1-2INTELLIGENT LINKINGAn intelligent link may be used to connect an Eclipse PiCo
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual1-3Figure 1-1: High Speed Link OperationIFB SupportThe High Speed Link supports t
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual1-4• Forced listens (normally made routes)• Port I/O level control• Local and glo
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual1-5ECLIPSE PICO APPLICATIONS The Eclipse PiCo is the perfect solution for high-qu
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual1-6A power-supply failure sensor is connected to a warning light, allowing power
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual1-7REMOTE INTERCOM PANELS AND ACCESSORY PANELS All analog intercom panels connect
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual1-8REMOTE INTERFACESInterface modules convert the 4-wire signals of a central mat
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual2-1OPERATING AN ECLIPSE PICO MATRIX STORING AND RETRIEVING CONFIGURA-TIONS A “co
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual2-2PC CONNECTOR The female 3.5 mm jack socket labeled “RS-232” connects the matri
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual2-3CONFIGURATION STATUS LIGHTS The four configuration status lights indicate whic
Eclipse PiCo Matrix Instruction Manual © 2007. 2009 Vitec Group Communications Ltd. All rights reserved.Part Number 810348Z Rev. 5Vitec Group Communi
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual2-4SETUP/ENTER KNOBThe setup/enter knob is used in conjunction with the display w
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual2-5CONNECTING THE MATRIX TO REMOTE DEVICESThe Eclipse PiCo matrix connects to rem
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual2-6detection allows the panel operator to know when the audio on a particular cha
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual2-7CONNECTING TO GENERAL-PURPOSE INPUTSThe female 25-pin D-type socket labeled “G
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual2-8Note: To transfer data between two linked PiCo matrices using the high-speed l
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual3-1USING THE PICO FRONT PANEL MENUS Using just the front-panel controls and d
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual3-2Scroll to a menu item by rotating the setup/enter knob. When the desired menu
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual3-3 Table 3-1: Port FunctionsNote: Ports 33 through 36 do not show the chequered
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual3-4Figure 3-6: Output Level MenuTo adjust a port’s incoming audio levels1. From t
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual3-5The audio level changes in real time as the setup/enter knob is rotated in the
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction ManualiCONTENTSINTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1Th
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual3-67. Press and release the setup/enter knob. 8. Rotate the setup/enter knob cloc
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual3-7The Configuration menu appears showing the names of each of the four onboard c
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual3-8The System menu appears.2. From the System menu, select IP ADDRESS. The IP Add
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual3-9ACCESSING SYSTEM INFORMATIONInformation about the system number and firmware v
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual3-10Figure 3-10: System Status Menu System Status This field shows the status of
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual3-115. Rotate the setup/enter knob clockwise or counterclockwise to scroll throug
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual3-12RESETTING THE SYSTEMResetting the system restores the currently selected conf
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual3-13CHECKING THE STATUS OF GENERAL PUR-POSE INPUTS (GPIS) It is possible to conne
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual3-14high-noise environment such as a control booth, it can be programmed as a rel
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-1INSTALLING AN ECLIPSE PICO MATRIX VERIFYING THE SHIPMENTWhen the Eclipse PiCo
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction ManualiiConnecting to a Second Eclipse PiCo Matrix . . . . . . . . . . . . . .2-7Connec
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-2A fully equipped Eclipse PiCo matrix requires 100 to 240 VAC at 50 to 60 Hz wi
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-3Figure 4-1: Wiring Interfaces to Rear-Panel ConnectorsWIRING TO AC MAINS POWER
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-4Figure 4-2: Wiring Matrix to Analog Panel Using RJ-45WIRING TO 4-WIRE EQUIPMEN
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-5• Pair 4 is not used.Figure 4-3: Wiring Matrix to 4-Wire Equipment Using RJ-45
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-6Figure 4-4: Wiring Matrix to Digital Panel Using RJ-45WIRING GENERAL-PURPOSE O
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-7Figure 4-5: Pin Configuration of the General-Purpose Outputs ConnectorWIRING G
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-8Non-Isolated ModeFigure 4-6 shows the non-isolated connection. Figure 4-6: Non
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-9 Figure 4-7: Opto-Isolated Connection to Eclipse PiCo GPI ConnectorIn this mod
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-10Pin Assignments for General-Purpose Inputs Connector Figure 4-8: Pin Assignme
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-11connection of up to 60 relays to the matrix. IMF-3 Interface Module Frame Wir
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction ManualiiiMAINTAINING AN ECLIPSE PICO MATRIX. . . . . . 5-1Recommended Spare Parts . . .
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-12Figure 4-9: Rear View of IMF-3 Frame To External DeviceTo connect external de
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-13Figure 4-10: RLY-6 Interface DB-9M Connector PinoutIMF-102 Interface Module F
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-14IMF-3 Interface Module Frame Wiring To MatrixTo connect the GPI-6 to the matr
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-15Figure 4-12: GPI-6 Application ExamplesFigure 4-11 and Figure 4-12 show how t
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-16.Table 4-1: Pin Configuration of Base Loop ConnectorNote: To transfer data be
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-17WIRING TO A COMPUTER The 3.5 mm connector on the PiCo unit’s front panel con
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual4-18
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual5-1MAINTAINING AN ECLIPSE PICO MATRIX RECOMMENDED SPARE PARTSTo facilitate quic
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual5-2
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual6-1SPECIFICATIONSECLIPSE PICO TECHNICAL SPECIFICATION0 dBu is referenced to 0.775
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manualiv
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual6-2External GPI-6/RLY-6 RJ-45 on rear panel Network 10/100 Base-T Ethernetmaximum
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual6-3Power Supply Unit Quantity 2 per matrix Mounting Internal AC Power Input IEC (
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual6-4
Vitec Group CommunicationsEclipse PiCo Matrix Instruction Manual7-1APPENDIX: PICO MENU MAP Figure 7-1: Eclipse PiCo Menu MapMain Menu
Vitec Group CommunicationsEclipse PiCo Matrix Instruction Manual7-2
Clear-Com Communication SystemsEclipse Glossary8-1GLOSSARYAnalog Port Any of the Eclipse matrix’s analog input/output RJ-45 connectors that are used t
Clear-Com Communication SystemsEclipse Glossary8-2Fiber-optic Cable A fiber-optic cable consists of a glass core covered with a reflective material ca
Clear-Com Communication SystemsEclipse Glossary8-3by manufacturers. Single-mode fiber evolved as production methods improved. Multiplexing The process
Clear-Com Communication SystemsEclipse Glossary8-4VOX In the Eclipse system, when audio at a panel exceeds a threshold, a light switches on at the pan
Clear-Com Communication SystemsEclipse Manuals8-5ECLIPSE MANUALSThe following manuals are available covering Eclipse products and accessories.SOFTWARE
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual iIMPORTANT SAFETY INSTRUCTIONS1. Read these instructions.2. Keep these instructi
Clear-Com Communication SystemsEclipse Manuals8-6Eclipse FIM-102 Fiber Interface Instruction Manual - 810319ZEclipse FIM-108 Fiber Interface Instructi
Clear-Com Communication SystemsStandard Limited WarrantyiLIMITED WARRANTYThis document details the Clear-Com Standard Limited Warranty for all new pro
Clear-Com Communication SystemsStandard Limited Warrantyii(5) All software products, including Concert (Client and Server), ECS, Production Maestro an
Clear-Com Communication SystemsStandard Limited Warrantyiiih) Software Upgrades i) Software Upgrades include new Features and/or Functional Enhancemen
Clear-Com Communication SystemsStandard Limited Warrantyiv
Clear-Com Communication SystemsTechnical Support & Repair PolicyvTECHNICAL SUPPORT & REPAIR POLICYNOVEMBER 1, 2008In order to ensure that your
Clear-Com Communication SystemsTechnical Support & Repair PolicyviDays: Monday - FridayTel: +49 40 853 999 700Email: TechnicalSupportEMEA@vitecgro
Clear-Com Communication SystemsTechnical Support & Repair Policyviid) Damaged equipment will be repaired at the Customer's expense.e) Returns
Clear-Com Communication SystemsTechnical Support & Repair Policyviiivii) Note: Shipping charges, including duties, taxes, and insurance (optional)
Clear-Com Communication SystemsTechnical Support & Repair Policyixthe cost of repair, the Customer may elect to return the product to the factory
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction ManualiiFigure ii-1: Safety SymbolsEMC AND SAFETYThe Eclipse PiCo matrix meet all relev
Clear-Com Communication SystemsEclipse PiCo Matrix Instruction Manual1-1INTRODUCTIONTHE ECLIPSE PICO MATRIX The Eclipse family of communications produ