Clear-Com HME DX210 Operations Instructions Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
Repeat these steps for each remaining secondary base station. Use a different number for each.
Only the primary base station and the secondary base station you are currently working with should
have power on during registration. All other equipment should be off.
After all secondary base stations are registered and COMMUNICATOR
®
s are registered, power up
all base stations. Press reset on the primary base station and let it recover. Turn on the primary
Communicators and let them link. Press the reset on each secondary base station one at a time and
let it link to the primary, as indicated by a single bar. Turn on the Communicators associated with the
secondary base stations. Do one group at a time until they have all linked. Then do the next group.
At this point all base stations and Communicators should be powered up and linked, ready for use.
Now proceed with normal system configuration, setting functions and levels as required.
If it becomes necessary to replace a secondary base station, use the procedure above to register the
new secondary with the same number as the old secondary. After registration, you will have to
register any Communicators associated with the old secondary to the new secondary base station.
If it becomes necessary to replace a primary base station, follow the above procedure completel
Before registration of the secondary base stations, clear the previous secondary registration as
follows. For each secondary, press the
y.
primary
have to be registered again.
n
o
ut down after
recognize
on, with the primary
base station remaining active and the secondary base station displaying one bar.
CLR/BND button and the RESET button at the same time.
Continue holding the
CLR/BND button after you release the RESET button, until the clear code “c
(lower case) appears on the
STATUS display. Any Communicators associated with the old
will have to be registered to the new primary after secondary base station registration. All
Communicators associated with secondary base stations also
If the primary base station is shut down or if the primary base
is powered off for more than 30 seconds, all secondary base
stations will drop their Communicator connections and begi
searching for the primary. If the primary is not found in 30
seconds, the secondary will automatically revert to primary-
mode operation and reconnect the Communicators. At this
point the secondary STATUS displays will show three bars.
If the primary is turned back on it will be necessary to press
RESET on all secondary base stations to allow them to find
and initialize to the primary again. It is therefore important t
have all base stations connected to the same AC circuit to
prevent this situation when the system is sh
Three bars
Secondary base station
operating in primary mode
when no primary base station
is found
hours and powered up again the next day.
NOTE: You cannot register Communicators to a base that is set to primary mode, and then switch the
base mode to secondary for registration. Once in secondary mode, the base station cannot
the Communicators registered during primary operation. For secondary base stations, the
Communicators must always be registered after secondary base station registrati
24
Clear-Com HME DX210 System Guide
Page view 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 36

Comments to this Manuals

No comments