RM-702 TWO-CHANNEL REMOTE STA-
4-1
TECHNICAL
SPECIFICATIONS
RM-702 TWO-CHANNEL STATION
dBu is an absolute measurement. 0 dBu is referenced to 0.775 volts RMS
Panel Microphone Input
Input Type Electret
Input Impedance >=2K
Ω
Mic Limiter Threshold 0dBu ±3dB
Mic Limiter Range >= 20dB
Headset Microphone Input
Input Type Dynamic
Input Impedance >= 1K
Ω
Mic Limiter Threshold 0dBu ± 3dB
Mic Limiter Range >= 15dB
Program Line Input
Maximum Level before Clipping >= 20dBu
Input Impedance >= 5K
Ω
Headset Output
Load Impedance >= 8
Ω
Output Impedance <= 25
Ω
Output Limiter Threshold +5dBu ± 3dB
Maximum Output Level before Distortion >= 17dBu
Speaker Output
Load Impedance >= 4
Ω
Max Output Level before 1% Distortion 20dBu ± 2dBu
Party Line Output
Off Noise < -74dBu
Output Impedance >10K
Ω
Party Line Input
Crosstalk < -60dB
Max level before Clipping >= 12dBu
Sidetone Null Capability > 25dB
Stage Announce/Balanced Line Out
Type Balanced