RM-702 TWO-CHANNEL REMOTE STATION
2-12
TYPICAL SYSTEM APPLICATIONS
ENG/EFP TRUCK
The following block diagram describes a typical ENG/EFP truck installation.
Figure 2-10: Typical ENG/EFP Truck Installation
The system has two 2-channel RM-702 rack-mount stations. The system is
powered from a Clear-Com power supply that also provides the terminations
for both channels.
Channel B is connected to talent receivers for announcers.
A telephone line interface is connected to the program input of station #2. It
provides a program feed from the studio via a dial-up telephone line. Its
DIP switch options are set to insert program audio on channel B and interrupt
the program when a call signal is present on channel B. The option DIP
switches for placing a call signal on channel B is set on both RM-702s. Now,
whenever either RM-702 initiates a talk to the announcers, it interrupts the
program feed (to the announcers).
RM-702
Director
Engineer
Telephone Interface
RM-702
AC-701
Program Input
Power Supply
PS-702
Channel A
Camera
Operator
1-Channel Beltpack
Assistant Director/
Floor Manager
1-Channel Beltpack
Talent Announcer
TR-50
Channel B
Telco
Line