Clear-com HME DX100 User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 35
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
9
Multiple Base Stations
This mode of operation can be used to expand the number of users communicating through multiple HME Base
Stations operating in the same portion of the 2.4 GHz to 2.48 GHz frequency band.
Primary and Secondary Base Station Settings
One base station must be designated as “primary” and all others must be designated as “secondary”. You can have
only one primary and up to 3 secondary base stations. Secondary base stations are assigned numbers 1, 2, or 3.
Label the base stations as “Primary,” “1,” “2” and “3.”
Start with every base station and Beltpac/Headset power off.
Set DIP Switches
Open each secondary base station and set
DIP switch #4 to the ON position as follows.
Using a T9 torque wrench, remove the
six screws from the front panel of each
secondary base station. Lift the front
panel carefully and set it face down.
Be careful not to pull any wires loose.
Locate the DIP switch on the transceiver circuit board inside the front panel of each secondary base station.
Set DIP switch #4 to the ON position. Leave #s 1 and 3 in the OFF position.
Replace the front panel and screws on the secondary base stations.
The primary base station DIP switch #4 should be in the OFF position.
1
2
3
4
5
6
DIP switch inside
secondary
base station