Clear-com HX System Frames User Manual Page 237

  • Download
  • Add to my manuals
  • Print
  • Page
    / 290
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 236
Figure 9-4 Local Advanced Display with Online Active
9.4 Online limitations
Online mode provides much of the functionality of Panel Programming but it cannot be
used to create new entities. This must be done in EHX. Specifically Online mode cannot:
Create or edit a Party Line.
Create or edit a Fixed Group.
Create or edit a Control.
Create a Talk and Forced Listen key.
Create the first remote key to a Fixed Group.
Create the first remote key to a Party Line.
Create the first remote key to a Control.
Create a stacked key.
Also, as noted previously Online cannot assign a label that refers to a remote system
unless it is already present in the current map. In order for such a label to be present in a
configuration it must have been assigned at least once and then downloaded as part of a
map. In this way it is recognized by the matrix if it is assigned in Online mode.
9.5 Exiting online mode
1) To exit Online mode, click Go Offline.
The background color of the menu pane returns to gray. The button text changes
to Go Online.
At this point the configuration on EHX and on the matrix should be synchronized but the
configuration is not saved in the database at this point. The configuration on the matrix is
preserved in non-volatile memory in the event of a power failure but it is lost if a new
configuration is downloaded. Therefore it is highly recommended that after a configuration
237
Eclipse EHX Software User Guide
Page view 236
1 2 ... 232 233 234 235 236 237 238 239 240 241 242 ... 289 290

Comments to this Manuals

No comments