Clear-com SB-704 User Manual

Browse online or download User Manual for Accessories communication Clear-com SB-704. Clear-Com SB-704 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 42
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SB-704 MAIN STATION
INSTRUCTION MANUAL
CLEAR-COM ENCORE
Page view 0
1 2 3 4 5 6 ... 41 42

Summary of Contents

Page 1 - CLEAR-COM ENCORE

SB-704 MAIN STATIONINSTRUCTION MANUALCLEAR-COM ENCORE

Page 2 - China Office

SB-704 MAIN STATION1-4providing separate short-circuit-protected power sources to each of the four intercom lines. A short on one intercom line will n

Page 3 - CONTENTS

SB-704 MAIN STATION1-5as ½ second, depending upon whether there was a single or multiple short or overload. The other channels continue to operate nor

Page 4

SB-704 MAIN STATION1-6The main program input is the one on the XLR connector on the rear panel. To listen to the main program in the speaker or headph

Page 5 - INSTRUCTIONS

SB-704 MAIN STATION1-7button on the station will send the microphone to all channels in the party-line position.Remote Mic Kill Function When you pres

Page 6 - Figure 1: Safety Symbols

SB-704 MAIN STATION1-8• TALK LATCH DISABLE: Four DIP switches (one for each channel) disable the latching action of the selected channel.• PROGRAM ON/

Page 7 - OPERATION

SB-704 MAIN STATION1-94. Adjust the sidetone adjust control for the desired amount of sidetone in the headset. • CHANNEL PROGRAM FEED LEVEL: Beside th

Page 8 - DESCRIPTION

SB-704 MAIN STATION1-10intercom line and break it apart in several places while it is plugged into the station to isolate the section of line that is

Page 9

SB-704 MAIN STATION1-11Note: To “latch” (or “lock”) a button to “on,” quickly press it once. The button is “locked” to “on” for hands-free use. Pressi

Page 11 - Monitoring Main Program

SB-704 MAIN STATION2-1INSTALLATIONThis chapter describes installation of the SB-704 in an intercom system.INSTALLATION OVERVIEWThis section describes

Page 12 - The Announce Function

SB-704 Main Station Instruction ManualPart Number 810346Z Rev. 3Legal DisclaimersCopyright © 2013 HME Clear-Com Ltd.All Rights ReservedClear-Com, the

Page 13 - ADJUSTMENTS

SB-704 MAIN STATION2-2link is activated. If there is more than one SB-704 or MS-704 in a system, the link function can only be used at the station whe

Page 14 - Hidden Adjustment Controls

SB-704 MAIN STATION2-3• INDIVIDUAL CHANNEL SHORT CIRCUIT PROTECTION: Each individual channel is separately overload and short circuit protected and ma

Page 15 - Intercom Line Termination

SB-704 MAIN STATION2-4Figure 2-3: Fail Safe Power DistributionThe illustration above shows the proper power wiring of a system powered by a single SB-

Page 16 - LIGHTS, AND CONTROLS

SB-704 MAIN STATION2-5Portable Installation CablePractical cable for portable system interconnections is flexible, two-conductor, shielded microphone

Page 17

SB-704 MAIN STATION2-6Figure 2-4: Interconnect Cable DetailNote: The remote stations connected to each channel are powered from the intercom cable for

Page 18 - SB-704 MAIN STATION

SB-704 MAIN STATION2-7Figure 2-5: Typical Mixed System WiringPHYSICAL INSTALLATIONYou can install the SB-704 in a standard equipment rack, or you can

Page 19 - INSTALLATION

SB-704 MAIN STATION2-8(0.64 cm) phone jack for a connector. A proprietary mating receptacle is mounted on the station. To install a GM-9 or GM-18 pane

Page 20 - FAIL-SAFE POWER

SB-704 MAIN STATION2-9Pin 2 --- - SignalPin 3 --- + SignalThe signal level is 0 dBu and transformer isolated.IFB/HOT MIC (REAR PANEL, 1/4-INCH PHONE J

Page 21

SB-704 MAIN STATION2-10Figure 2-6: Accessory Connector DB-15F - Rear ViewAuxiliary Program InputsFour different program inputs, one for each channel,

Page 22 - Station

SB-704 MAIN STATION2-11INTERNAL OPTION JUMPERSThere are several jumper options inside the chassis of the SB-704. To access these options remove the to

Page 23 - GROUND ISOLATION

SB-704 MAIN STATION iCONTENTSOPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1Introduction . . . . . . . . . . . . .

Page 24

SB-704 MAIN STATION2-12announce output and replaces it with audio from the selected panel or headset microphone.The factory default position for J11 i

Page 27 - 1/4-INCH PHONE JACK)

SB-704 MAIN STATION3-1MAINTENANCEINTRODUCTIONThis chapter provides maintenance information, including a block diagram and troubleshooting tips. Cautio

Page 28 - Announce Relay Contacts

SB-704 MAIN STATION3-2Figure 3-8: SB-704 Block Diagram

Page 29 - OUTPUT JUMPER

SB-704 MAIN STATION4-1TECHNICAL SPECIFICATIONSSB-704 MAIN STATIONdBu is an absolute measurement. 0 dBu is referenced to 0.775 volts RMSPanel Micropho

Page 30 - ABLE INTERCOM LINES

SB-704 MAIN STATION4-2Output Impedance >= 200ΩLoad Impedance >= 600ΩIFB/Hot MicType UnbalancedOutput Impedance 150ΩLoad Impedance >= 600ΩFre

Page 31

SB-704 MAIN STATION4-3Min GainPanel Mic - Party Line <= 25dBMains PowerInput Voltage Range 100 - 240 VACInput Frequency Range 50 - 60 HzInput Power

Page 32

SB-704 MAIN STATION4-4(4) Listen adjust controls(4) Channel null adjust controls(4) Channel program feed adjust controls(4) Talk buttons(4) Call butt

Page 33 - MAINTENANCE

WARRANTY iLIMITED WARRANTYClear-Com warrants that at the time of purchase, the equipment supplied complies with any specifica

Page 34

SB-704 MAIN STATIONiiAccessory (Rear Panel, DB-15F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8Auxiliary Program Inputs. . . . .

Page 35 - SPECIFICATIONS

WARRANTYii period will be offered at no charge between 09:00 and 17:00 according to the customer’s local time zone.In addition, for cus

Page 36

WARRANTY iiiNON-WARRANTY REPAIRS AND RETURNSFor items not under warranty, you must obtain an RMA by contacting the User Suppo

Page 37

WARRANTYiv EVENT, TO THE MAXIMUM EXTENT PERMITTED UNDER APPLICABLE LAW, CLEAR-COM'S LIABILITY TO CUSTOMER HEREUNDER SHALL NOT UNDE

Page 38 - Notice About Specifications

SB-704 MAIN STATION iiiIMPORTANT SAFETY INSTRUCTIONS1. Read these instructions.2. Keep these instructions.3. Heed all warnings.4. Follow all instructi

Page 39 - WARRANTY

SB-704 MAIN STATIONivFigure 1: Safety SymbolsEMC AND SAFETYThe SB-704 station meets all relevant CE, FCC, UL, and CSA specifications set out below:EN5

Page 40 - WARRANTY REPAIRS AND RETURNS

SB-704 MAIN STATION 1-1OPERATIONINTRODUCTIONCongratulations on choosing this Clear-Com product. Clear-Com was established in 1968 and remains the mark

Page 41 - LIABILITY

SB-704 MAIN STATION1-2Clear-Com main stations, power supplies, and certain remote stations each have an auxiliary program input with its own volume co

Page 42

SB-704 MAIN STATION1-3• INTERNAL IFB (IFB - Interrupt Foldback of program feeds): Program feed can be fed to each channel and interrupted (IFB) when a

Comments to this Manuals